2009 — Deutsch Connector Repair

HOME NOTE Seal plugs (6) are installed through the wire seals of unused chambers. If removed, seal plugs must be replaced to seal the connector. sm00018 5. Install internal seal (4) on lip of socket housing, if removed. 2 6. Insert tapered end of secondary locking wedge (5) into socket housing and press down until it snaps in place.The wedge fits into the center groove within the socket housing and holds the terminal latches tightly closed. NOTES • See Figure A-18 .While rectangular wedges do not require a special orientation, the conical secondary locking wedge of the 3-place connector must be installed with the arrow (1) pointing toward the external latch.

1 • If the secondary locking wedge does not slide into the installed position easily, verify that all terminals are fully installed in the socket housing. The lock indicates when terminals are not properly installed by not entering its fully installed position. Figure A-17. Deutsch Connector: Remove Secondary Locking Wedge A-12 2009 VRSC Service: Appendix A Connector Repair sm00009 1. Arrow on socke 2. Arrow on pin loc Figure A-18. Deutsch C t locking wedge king wedge