2009 — Metri-Pack Terminal Crimps

HOME A.15 PACKARD METRI-PACK TERMINALS Figure A-43. Metri-Pack Terminal Crimp Tools Crimping Insulation/Seal NOTE Always perform Crimping Wire Core before Crimping Insu- lation/Seal . A-28 2009 VRSC Service: Appendix A Connector Repair sm00035 PART NUMBER TOOL NAME HD-38125-6 PACKARD TERMINAL CRIMP TOOL HD-38125-7 PACKARD TERMINAL CRIMPER HD-38125-8 PACKARD CRIMPING TOOL Matching Terminal To Crimper Metri-Pack connectors embossed with the initials P.E.D. require Packard crimp tools to crimp terminals to wire leads. 1 Terminals are crimped twice to a wire lead, once over the wire core and a second time over the insulation/seal. See Figure A-43.

A completed crimp may require two different crimping dies found on PACKARD TERMINAL CRIMP TOOL (Part No. HD-38125-6) and/or PACKARD TERMINAL CRIMPER (Part No. HD-38125-7).The terminal (pin or socket) and the wire lead gauge will determine the core crimp die and the insulator/seal die. NOTE The PACKARD CRIMPING TOOL (Part No. HD-38125-8) will also crimp sealed splice connectors in wire gauge sizes 18-20, 2 14-16 and 10-12. Preparing Wire Lead Use a wire striper to strip off the insulation and expose 4.0 mm (5/32 in.) of wire core. Crimping Wire Core NOTE Metri-Pack terminal crimps require two steps. Always perform Crimping Wire Core before Crimping Insulation/Seal. 1.

Squeeze and release handles until ratchet automatically opens. 3 2. Identify the corresponding sized nest for the core crimp. 3. Position the core crimp in the die. Be Sure the core crimp tails are facing the forming jaws. 4. Gently squeeze the handles until crimpers just secure the core crimp tails. 5. Insert stripped wire between crimp tails. Verify that wire is positioned so that short pair of crimp tails squeeze core wire strands, while long pair is positioned over the insula- tion or seal material. 1. HD- 6. Squeeze handles tightly closed. Release grip and the tool 2. HD- will automatically open. 3. HD- 38125-6 sealed terminals 38125-7 non-sealed terminals 38125-8 non-sealed terminals