User Manual of A90 Series Inverter (Remote Terminal Unit) message, and end tag. RTU message PDU Start End ≥3.5 characters ≥3.5 characters Fig. 0-1 Schematic Diagram of Message Frame in RTU Mode The RTU message includes the address code, PDU (Protocol Data Unit) and CRC[3 ] check. The PDU includes the function code and data part (mainly including the register address, number of registers, register content and the like; the detailed definitions of function codes are different, as shown in 0 Function code). [3]: the low byte of CRC check is in front of the high byte. 12.3.2 Address code 12.3.3 Function code The classification of MODBUS function codes is shown in Fig. 0-2.
272 Address Function code Data CRC check 8 digits 8 digits N*8 bits 2*8 bit Address of register Number of registers Register content 2*8 bit 2*8 bit 2 * number of registers * 8 bits Address Range Purpose 1 - 247 Slave 0 Broadcast