sinee — A90 User Manual

User Manual of A90 Series Inverter information about the latest fault): According to the returned data, the “17 (0011H): temperature sensor abnormality” occurs to the inverter, in which the output frequency is 0.00Hz, the output current is 0.00A, the bus voltage is 300V (012CH), the acceleration and deceleration status is “standby”, and the working time is 0 hour. ★ :

At present, the function code 0x03 of MODBUS protocol supports the reading of 275 Request Respond Domain name (0x) Domain name (normal) (0x) Domain (0x) name (abnormal) Function code 03 Function code 03 Function 83 Starting address 13 Number of bytes 0C 03 (example, the same below) Hi Exception Starting address 00 Register value Hi 00 code Lo (F19.00) Number (Hi) of 00 Register value Lo 11 registers (F19.00) Number (Lo) of 06 Register value Hi 00 registers (F19.01) Register value Lo 00 (F19.01) Register value Hi 00 (F19.02) Register value Lo 00 (F19.02) Register value Hi 01 (F19.03) Register value Lo 2C (F19.03) Register value Hi 00 (F19.04) Register value Lo 00 (F19.04) Register value Hi 00 (F19.05) Register value Lo 00 (F19.05)