sinee — A90 User Manual

User Manual of A90 Series Inverter The user-defined function code 0x41 “change without saving” corresponds to the standard common function code 0x06. Its definition is the same as that of the corresponding standard function code (the same request, response and error PDU). The difference is that when the slave responds to this user-defined function code, the corresponding value of RAM is changed only and not stored in EEPROM (holding register). For the function codes (e.g. F00.07) that are often modified, it is recommended to use the function code 0x41 (you can change the main frequency source A by directly setting 7001H, as detailed in 0 and 0), to avoid damage to the inverter.

The specific operation is as follows. Once the set frequency (F00.07) is set to 50.00Hz, the above data will be valid but not be stored in EEPROM. That is, the inverter will run at 50.00Hz after change but at the frequency before change if powered on again. 12.3.3.6 0x10: function code used to write multiple registers or commands blocks (1 to 16 registers). In the remote terminal unit, this function code is used to write consecutive register The value requested to be written is described in the request data field. The data of each register is divided into two bytes. written will be returned.

In the normal response, the function code, starting address and number of registers  Request PDU 281 Request Respond Domain name (0x) Domain name (0x) (normal) Function 41 Function 41 Register address Hi 00 Register address Hi 00 Register address Lo 07 Register address Lo 07 Register value Hi 13 Register value Hi 13 Register value Lo 88 Register value Lo 88 Function code 1 byte 0x10 Starting Address 2 bytes 0x0000 - 0xFFFF Number of registers 2 bytes 1 - 16 Number of bytes 1 byte 2×N* Register value N*×2 bytes