Mitsubishi — 5.8.1.3 Installing the DeviceNet Connector

AH500 Hardware Manual 5.8.1.2 Connecting a Cable to the DeviceNet Connector  Remove the 30 millimeter plastic jacket of a cable with a professional tool. Please do not damage the shielded cable when the plastic jacket is removed. Approximately 30 mm  After users remove the metallic shield and the foil, they can see two power cables (in red and black respectively), two signal cables (in blue and white respectively), and one shielded cable. Shielded cable  After the metallic shield and the foil are removed, the users need to remove the plastic jackets of the power cables and the plastic jackets of the signal cables properly.

Black (V-) Blue (CAN_L)  Insert the communication cable into the holes in the connector. Shielded cable (CAN_SHLD) Red (V+) White(CAN_H)  After the communication cable is inserted into the holes in the connector, tighten the screws on the connector with a slotted screwdriver. 5.8.1.3 Installing the DeviceNet Connector  After the wiring is complete, users can insert the DeviceNet connector into the interface.  Tighten the two screws on the DeviceNet connector. Points for attention:  After the communication cable is kept separate from the power cable, the electromagnetic interference is reduced.

 Only after the both ends of the shielded cable are grounded can the shielded cable be brought into full play. 5-54