Mitsubishi — 7.1 Functions of Uniaxial Motion

Chapter 7 Uniaxial Motion *4. N is in the range of 0 to 15. *5. Only AH20MC-5A is supported. The special data registers related to uniaxial motion are described below. 7-5 Motion SR number JOG motion Returning home Single-speed motion Inserting single-speed motion Two-speed motion Inserting two-speed motion Variable motion Manual pulse generator mode (1+N)th axis Function HW LW - SR1000+100*N Setting the parameters of the axis specified ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ SR1003+100*N SR1002+100*N Number of pulses it takes for the motor of the axis specified to rotate once (A) If the unit selected is a motor unit, users do not need to set SR1002+100*N and SR1003+100*N.

If the unit selected is a mechanical unit or a compound unit, users need to set SR1002+100*N and SR1003+100*N.

SR1005+100*N SR1004+100*N Distance generated after the motor of the axis specified rotate once (B) SR1007+100*N SR1006+100*N Maximum speed (V ) at which the MAX axis specified rotates ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ SR1009+100*N SR1008+100*N Start-up speed (V ) BIAS at which the axis specified rotates ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ SR1011+100*N SR1010+100*N JOG speed (V ) at JOG which the axis specified rotates ◎ - - - - - - - SR1013+100*N SR1012+100*N Speed (V ) at which RT the axis specified returns home - ◎ - - - - - - SR1015+100*N SR1014+100*N Speed (V ) to which CR the speed of the axis specified decreases when the axis returns home - SR1016+100*N Number of PG0 pulses for the axis specified - SR1017+100*N Supplementary pulses for the axis specified SR1019+100*N SR1018+100*N Home position of the axis specified - ◎ - - - - - - - SR1020+100*N Time (T ) it takes for ACC the axis specified to accelerate ◎ ◎ ◎ ◎ ◎ ◎ ◎ -