Mitsubishi — 7.1 Functions of Uniaxial Motion

Chapter 7 Uniaxial Motion *1. Only AH20MC-5A is supported.

7-7 Motion SR number JOG motion Returning home Single-speed motion Inserting single-speed motion Two-speed motion Inserting two-speed motion Variable motion Manual pulse generator mode (1+N)th axis Function HW LW SR1047+100*N SR1046+100*N Number of pulses generated by the manual pulse generator for the axis specified - - - - - - - ◎ - SR1048+100*N Response speed of the manual pulse generator for the axis specified - - - - - - - ◎ - SR1049+100*N Mode of stopping Ox0~Ox99 - - - - - - - - SR1051+100*N SR1050+100*N Electrical zero of the axis specified - - - - - - - - - SR1052+100*N Setting an Ox motion subroutine number - - - - - - - - - SR1053+100*N Step address in the Ox motion subroutine at which an error occurs - - - - - - - - SR1069+100*N SR1068+100*N Present position of the encoder specified on a DMCNET*1 ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎