Mitsubishi — 7.1 Functions of Uniaxial Motion

AH500 Motion Control Module Manual Common special data registers are described below. 1. Setting the parameters of the axis specified [Description] Bit 0~bit 15 in SR1000+100*N are described below.  Bit 0 and b1 in SR1000+100*N: Unit  Position: Home position of the axis specified, target position of the axis specified (P (I)), target position of the axis specified (P (II)), and present command position of the axis specified  Speed:

Maximum speed (V MAX ) at which the axis specified rotates, start-up speed (V BIAS ) at which the axis specified rotates, JOG speed (V JOG ) at which the axis specified rotates, speed (V RT ) at which the axis specified returns home, speed (V CR ) to which the speed of the axis specified decreases when the axis returns home, speed at which the axis specified rotates (V (I)), and speed at which the axis specified rotates (V (II)) 7-8 (1+N)th axis HW LW - SR1000+100*N Special data register SR1000+100*N b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 - Curve Mode of triggering the calculation of the target position Relative/Absolute coordinates Direction in which the motor used rotates Mode of triggering the return to home Mode of returning home Direction in which the axis specified returns home - - Output type (positive logic) - Unit b1 b0 Unit Description 0 0 Motor unit A pulse is a unit.

0 1 Mechanical unit A micrometer, 10-4 inches, or a degree is a unit. 1 0 Compound unit Position: A micrometer, 10-4 inches, or a degree is a unit. (Mechanical unit) Speed: A pulse is a unit. (Motor unit) 1 1 Motor unit Compound unit Mechanical unit pulse µm Position pulse mdeg pulse 10-4 inches pulse/second centimeter/minute Speed pulse/second 10 degrees/minute pulse/second inch/minute