Mitsubishi — 7.1 Functions of Uniaxial Motion

AH500 Motion Control Module Manual  Bit 4 and bit 5 in SR1000+100*N: Output type  Bit 8 in SR1000+100*N: Direction in which the axis specified returns home  Bit 9 in SR1000+100*N: Mode of returning home  Bit 10 in SR1000+100*N: Mode of triggering the return to home Please refer to section 7.6 for more information about bit 8, bit 9, and bit 10 in SR1000+100*N.  Bit 11 in SR1000+100*N: Direction in which the motor used rotates (1) Bit 11=0: When the motor rotates clockwise, the value indicating the present position of the axis increases. (2) Bit 11=1: When the motor rotates clockwise, the value indicating the present position of the axis decreases.  Bit 12 in SR1000+100*N:

Relative/Absolute coordinates (1) Bit 12=0: Absolute coordinates (2) Bit 12=1: Relative coordinates  Bit 13 in SR1000+100*N: Mode of triggering the calculation of the target position Please refer to section 7.1 fore more information. (The setting of bit 13 in SR1000+100*N is applicable to inserting single-speed motion and inserting two-speed motion.)  Bit 14 in SR1000+100*N: Curve (1) Bit 14=0: Trapezoid curve (2) Bit 14=1: S curve 2.

Number of pulses it takes for the motor of the axis specified to rotate once (A) [Description]  Owing to the fact that users can set an electronic gear ratio for a servo drive, the number of pulses it takes for a servo motor to rotate once is not necessarily equal to the number of pulses which will be generated after an encoder rotates once. The relation between the number of pulses it takes for a servo drive to rotate once and an electronic gear ratio is described below. Number of pulses it takes for a motor to rotate once (A) x Electronic gear ratio (CMX/CDV) = Number of pulses which will be generated after an encoder rotates once Example:

If the number of pulses it takes for a motor to rotate once is 20,000, and the resolution of Delta ASDA-A2 series servo drive is 1,280,000, the gear ratio which should be set is 128/2.  The unit used is determined by bit 0 and bit 1 in SR1000+100*N. If the unit selected is a mechanical unit or a compound unit, users need to set SR1002+100*N and SR1003+100*N.

If 7-10 b5 b4 Output type (positive logic) Description 0 0 FP Clockwise pulses RP Counterclockwise pulses Counting up/down 0 1 FP Pulses Clockwise Counterclockwise RP Directions Pulses+Directions 1 0 FP A-phase pulses RP B-phase pulses Clockwise Counterclockwise A/B-phase pulses 1 1 Four times the frequency of A/B-phase pulses (1+N)th axis HW LW SR1003+100*N SR1002+100*N