Mitsubishi — 7.2 Introduction of Uniaxial Motion

AH500 Motion Control Module Manual 13. Mode of operation [Description] Bit 0~bit 15 in SR1031+100*N are described below.  Bit 2: Mode of sending a CLR signal (1) Bit 2=0: After the axis returns home, the CLR output will send a 130 millisecond signal to the servo drive, and the present position of the servo drive which is stored in a register in the servo drive will be cleared. (2) Bit 2=1: The CLR output functions as a general output.  Bit 15: Restoring the module to the factory settings 7.2 Introduction of Uniaxial Motion (1) Bit 15=1: The values of parameters are restored to factory settings. 1. There are eight modes of motion. 1. Returning home 5. Two-speed motion 2. JOG motion 6.

Inserting two-speed motion 3. Single-speed motion 7. Variable motion 4. Inserting single-speed motion 8. Manual pulse generator mode 2. If more than one mode of motion is activated, they will be executed in particular order. 1. Stopping the motion of the axis specified by software. 6. Variable motion 2. Returning home 7. Single-speed motion 3. Positive JOG motion 8. Inserting single-speed motion 4. Negative JOG motion 9. Two-speed motion 5. Manual pulse generator mode 10. Inserting two-speed motion If a mode of motion is activated when another mode of motion is executed, the AH500 series motion control module will continue executing the original mode.

7-14 (1+N)th axis HW LW - SR1031+100*N Special data register SR1031+100*N b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 Restoring the module to the factory settings - - - - - - - - - - - - Mode of sending a CLR signal - -