Chapter 7 Uniaxial Motion Velocity V MAX V JOG V BIAS T A T D 7.4 Introduction of Variable Motion 7.4.1 Related Special Data Registers [Description] The value in (SR1025+100*N, SR1024+100*N) is in the range of 0 to +2,147,483,647. The unit used is determined by bit 0 and bit 1 in SR1000+100*N. The frequency of pulses generated by motion is in the range of 10 PPS to 1000K PPS. If the value in (SR1025+100*N, SR1024+100*N) is greater than 1000K, the frequency of pulses generated will be 1000K PPS. If the value in (SR1025+100*N, SR1024+100*N) is less than 10, the frequency of pulses generated will be 10 PPS.
V MAX > V (I) > V BIAS When bit 4 in SR1030+100*N is ON, the speed at which the axis specified rotates (V (I)) can be changed. 2. Operation command 1. Speed at which the axis specified rotates (V (I)) [Description] 7-17 (1+N)th axis HW LW SR1025+100*N SR1024+100*N (1+N)th axis HW LW - SR1030+100*N Special data register SR1030+100*N b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 - - - The execution of the Ox motion subroutine set starts. A mode of inserting two-speed motion is activated. A mode of two-speed motion is activated. A mode of inserting single-speed motion is activated. A mode of single-speed motion is activated. - A mode of triggering the return to home is activated.
A manual pulse generator is operated. A mode of variable motion is activated. The axis specified operates in JOG- mode. The axis specified operates in JOG+ mode. - The motion of the axis specified is stopped by software.