AH500 Motion Control Module Manual If users want to activate a mode of variable motion, they have to set bit 4 in SR1030+100*N to 1. 7.4.2 Operation After bit 4 in SR1030+100*N is set to 1, the AH500 series motion control module will execute variable motion. AH10PM-5A, AH15PM-5A, and AH05PM-5A send pulses by pulse generators. AH20MC-5A sends pulses to a servo drive by means of the DMCNET. After a mode of variable motion is activated, the V BIAS of the axis specified will increase to its V (I). When the axis operates, users can change its V (I) at will. The AH500 series motion control module accelerates or decelerates according to the V (I) set.
Diagram Velocity Time 7.5 Introduction of a Manual Pulse Generator Mode 7.5.1 Related Special Data Registers 1. Electronic gear ratio of the axis specified [Description] If bit 5 in SR1030+100*N is set to ON, a manual pulse generator mode will be activated. A manual pulse generator generates A/B-phase pulses that are sent to an input terminal. The relation between the position of the axis specified and the input pulses generated by the manual pulses used is shown below.
Servo motor Frequency of input pulses X SR1042(SR1142,...) SR1043(SR1143,...) FP Servo drive B phase A phase = Frequency of output pulses RP The speed output is determined by the frequency of input pulses generated by a manual pulse generator and an electronic gear ratio. 7-18 T T ACC DEC V MAX V(I) V BIAS Start: Bit 4 =0 -> 1 Stop: Bit 4 = 1-> 0 T ACC T DEC V MAX V(I) V BIAS (1+N)th axis Electronic gear ratio HW LW - SR1042+100*N Electronic gear ratio (Numerator) - SR1043+100*N Electronic gear ratio (Denominator)