Chapter 7 Uniaxial Motion the frequency of pulses generated will be 10 PPS. V MAX >V RT >V BIAS When an axis returns home, the speed at which the axis returns home can not be changed. 2. Speed (V CR ) to which the speed of the axis specified decreases when the axis returns home [Description] The value in (SR1015+100*N, SR1014+100*N) is in the range of 1 to 2,147,483,647. (The unit used is determined by bit 0 and bit 1 in SR1000+100*N.) The frequency of pulses generated by motion is in the range of 10 PPS to 1000K PPS. If the value in (SR1015+100*N, SR1014+100*N) is greater than 1000K, the frequency of pulses generated will be 1000K PPS.
If the value in (SR1015+100*N, SR1014+100*N) is less than 10, the frequency of pulses generated will be 10 PPS. When motion of returning home is executed, the speed of the motor used is the V RT set. When there is a transition in DOG’s signal from low to high or from high to low, the speed of the motor used decreases to the V CR set. In order for the axis specified to returns home precisely, it is suggested that the V CR set should be a low speed. When the motion of returning home is executed, the V RT set can not be changed. 3. Number of PG0 pulses for the axis specified [Description] The value in SR1016+100*N is in the range of 0 to 65,535. It is a positive value.
Please refer to the descriptions of bit 9 and bit10 in SR1000+100*N for more information about decelerating and stopping the motor used. 4. Supplementary pulses for the axis specified [Description] The value in SR1017+100*N is in the range of -32,768 to 32,767. If the value in SR1017+100*N is a positive value, the axis specified will move in the direction in which it returns home. If the value in SR1017+100*N is a negative value, the axis specified will move in the direction which is opposite to the direction in which it returns home. Please refer to the descriptions of bit 9 and bit10 in SR1000+100*N for more information about decelerating and stopping the motor used. 5.
Home position of the axis specified [Description] The value in (SR1019+100*N, SR1018+100*N) is in the range of 0 to ±999,999. (The unit used is determined by bit 0 and bit 1 in SR1000+100*N.) After the axis specified returns home, the value in (SR1019+100*N, SR1018+100*N) will be 7-21 (1+N)th axis HW LW SR1015+100*N SR1014+100*N (1+N)th axis HW LW - SR1016+100*N (1+N)th axis HW LW - SR1017+100*N (1+N)th axis HW LW SR1019+100*N SR1018+100*N