Mitsubishi — 7.6.2 Operation

AH500 Motion Control Module Manual Steps: (1) The motor used rotates at the speed V RT . (2) When DOG’s signal is generated, the speed of the motor begins to decrease to the speed V CR . (3) After DOG’s signal goes from high to low, the motor will rotate for a specific number of PG0 pulses, and then rotate for a specific number of supplementary pulses, and finally stop. If the number of PG0 pulses or the number of supplementary pulses is not large, the speed of the motor used will decrease to the speed V CR after DOG’s signal is generated.

After DOG’s signal goes from high to low, the motor will rotate for a specific number of PG0 pulses, and then rotate for a specific number of supplementary pulses, and finally stop whether the its speed is V CR . If the number of PG0 pulses is 0, and the number of supplementary pulses is 0, the motor used will stop after DOG’s signal is generated and there is a transition in DOG’s signal from high to low. Velocity (PPS) Away from DOG's signal Close to DOG's signal V RT Direction in which the axis specified returns home V CR V CR Number of supplementary pulses Number of PG0 pulses DOG A transition in DOG's signal from high to low.  Bit [9:10] in SR1000+100*N is 01.

 The mode of returning home is a normal mode, and the return to home is not triggered by a transition in DOG’s signal from high to low. Steps: (1) The motor used rotates at the speed V RT . (2) When DOG’s signal is generated, the speed of the motor begins to decrease to the speed V CR . After the motor rotates for a specific number of PG0 pulses, and rotate for a specific number of supplementary pulses, it will stop. If the number of PG0 pulses or the number of supplementary pulses is not large, the speed of the motor used will decrease to the speed V CR after DOG’s signal is generated.

After the motor rotates for a specific number of PG0 pulses, and rotates for a specific number of supplementary pulses, it will stop whether its speed is V CR . If the number of PG0 pulses is 0, and the number of supplementary pulses is 0, the motor used will stop after DOG’s signal is generated. 7-24