Mitsubishi — 7.7.1 Related Special Data Registers

AH500 Motion Control Module Manual and the return to home is not triggered by a transition in DOG’s signal from high to low. Steps: (1) The motor used rotates at the speed V RT . (2) When DOG’s signal is generated, the speed of the motor begins to decrease to the speed V CR . After the motor rotates for a specific number of PG0 pulses, or rotate for a specific number of supplementary pulses, it will stop. If the number of PG0 pulses or the number of supplementary pulses is not large, the speed of the motor used will decrease to the speed V CR after DOG’s signal is generated.

After the motor rotates for a specific number of PG0 pulses, or rotates for a specific number of supplementary pulses, it will stop whether its speed is V CR . If the number of PG0 pulses is 0, and the number of supplementary pulses is 0, the motor used will stop after DOG’s signal is generated. Velocity (PPS) Away from DOG's signal Close to DOG's signal V RT V CR V CR Direction in which the axis specified returns home Number of supplementary pulses Number of PG0 pulses DOG 7.7 Introduction of Single-speed motion 7.7.1 Related Special Data Registers 1.

Target position of the axis specified (P (I)) [Description]  The value in (SR1023+100*N, SR1022+100*N) is in the range of -2,147,483,648 to +2,147,483,647. (The unit used is determined by bit 0 and bit 1 in SR1000+100*N.)  Target position (P (I))  Absolute coordinates: Bit 12 in SR1000+100*N is 0. The target position of the axis specified indicates a distance from 0. If the target position of an axis is greater than its present command position, the motor used will rotate clockwise. If the target position of an axis is less than its present command position, the motor used will rotate counterclockwise.  Relative coordinates:

Bit 12 in SR1000+100*N is 1 The target position of an axis indicates a distance from its present command position. If the target position specified is a positive value, the motor used will rotate clockwise. If the target position specified is a negative value, the motor used will rotate counterclockwise. 7-26 (1+N)th axis HW LW SR1023+100*N SR1022+100*N