Mitsubishi — 7.8.2 Operation

Chapter 7 Uniaxial Motion [Description] Please refer to the descriptions of common special data registers in section 7.1 for more information.  Mode of triggering the calculation of the target position 3. Setting parameters  Bit 13=0: The calculation of the target position of the axis specified is triggered by a transition in DOG’s signal from low to high.  Bit 13=1: The calculation of the target position of the axis specified is triggered by a transition in DOG’s signal from high to low. 4. Operation command [Description]  If users want to activate a mode of inserting single-speed motion, they have to set bit 9 in SR1030+100*N to 1.

7.8.2 Operation  After bit 9 in SR1030+100*N is set to 1, a mode of inserting single-speed motion will be activated. The AH500 series motion control modules used sends pulses by pulse generators. After DOG’s signal goes from low to high or from high to low, the axis specified will move to the relative target position indicated by the P (I) set. If the value in (SR1023+100*N, SR1022+100*N) is 0, an error will occur.  Direction: If the target position (P (I)) specified is a positive value, the motor used will rotate clockwise. If the target position (P (I)) specified is a negative value, the motor used will rotate counterclockwise.  Steps:

 The speed of motion will increase from the V BIAS set to the V (I) set.  After DOG’s signal goes from low to high or from high to low, the AH500 series motion control modules used will continue sending pulses. The speed of the motion will not 7-29 (1+N)th axis HW LW - SR1000+100*N (1+N)th axis HW LW - SR1030+100*N Special data register SR1030+100*N b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 - - - The execution of the Ox motion subroutine set starts. A mode of inserting two-speed motion is activated. A mode of two-speed motion is activated. A mode of inserting single-speed motion is activated. A mode of single-speed motion is activated.

- A mode of triggering the return to home is activated. A manual pulse generator is operated. A mode of variable motion is activated. The axis specified operates in JOG- mode. The axis specified operates in JOG+ mode. - The motion of the axis specified is stopped by software.