AH500 Motion Control Module Manual decrease from the V (I) set to the V BIAS set until the number of pulses output is near the P (I) set. Velocity Time Start DOG 7.9 Introduction of Two-speed Motion 7.9.1 Related Special Data Registers 1. Target position of the axis specified (P (I)) [Description] Please refer to section 7.7 for more information. 2. Speed at which the axis specified rotates (V (I)) [Description] When an axis operates, users can not change its V (I) at will. Please refer to section 7.7 for more information. 3. Target position of the axis specified (P (II)) [Description] The value in (SR1027+100*N, SR1026+100*N) is in the range of -2,147,483,648 to +2,147,483,647.
(The unit used is determined by bit 0 and bit 1 in SR1000+100*N.) Target position (P (II)) Absolute coordinates: Bit 12 in SR1000+100*N is 0. The direction in which the axis specified moves from its P (I) to its P (II) must be the same as the direction in which it moves from its present command position to it P (I). Relative coordinates: Bit 12 in SR1000+100*N is 1 If the P (I) specified is a positive value, the P (II) is also a positive value. If the P (I) specified is a negative value, the P (II) is also a negative value.
The direction in which the axis specified moves from its P (I) to its P (II) must be the same as the direction in which it moves from its present command position to it P (I). 7-30 TACC TDEC VMAX V(I) P(I) VBIAS TACC TACC TDEC VMAX V(I) P(I) VBIAS V(I) VBIAS (1+N)th axis HW LW SR1023+100*N SR1022+100*N (1+N)th axis HW LW SR1025+100*N SR1024+100*N (1+N)th axis HW LW SR1027+100*N SR1026+100*N