Mitsubishi — 8.2.2.2 Setting the Starting Angle of a Master Axis

AH500 Motion Control Module Manual 8.2.2.2 Setting the Starting Angle of a Master Axis Users can set the starting angle of the master axis specified by means of the MasterOffset input pin in the motion control function block T_CamIn. 1.

Value of the Masteroffset input pin Displacement of the slave axis Starting the electronic cam MasterOffset=0 50 100 Position of the master axis Starting the electronic cam Displacement of the slave axis 25 50 100 Position of the master axis Starting the electronic cam MasterOffset=50 Displacement of the slave axis 50 100 Position of the master axis 8-6 Input value Definition Description K0~K2,147,483,647 Starting angle of the master axis specified A pulse is a unit. The value of the Masteroffset input pin indicates the starting point of a cam curve. MasterOffset=25