AH500 Motion Control Module Manual Example: G01 X200.0 Y400.0 Z250.0 F400.0 The instruction moves three axes from the present position (0, 10.0, 100.0) to the target position (200.0, 400.0, 250.0). If G90 precedes the instruction, the target position is an absolute position. If G91 precedes the instruction, the target position is a relative position. The speed at which the x-axis, the y-axis, and the z-axis move is 400 kHz. Path: X-axis Target position Z-axis Present position Y-axis 9-8