Mitsubishi — 9.4 Descriptions of G-code Instructions

AH500 Motion Control Module Manual  Circular interpolation: Two axes which are perpendicular to each other are used. G17, G18, or G19 is used to control circular interpolation. Y-axis G03 Arc start point (P resent position) Arc center point ( , ) I J G02 Arc center point ( , ) X P YP 1 2  Helical interpolation: Three axes which are perpendicular to one another are used. They move synchronously. Helical interpolation is the extension of circular interpolation. If a helical interpolation instruction is used, and the change of height is zero, circular interpolation will be executed.

 If G17 is used, and the position of a z-axis does not change, helical interpolation will be equivalent to circular interpolation. X-axis Z-axis Z-axis End point End point (x, y, z) ( x, y, z) End point (x, y) End point ( x, y) Y-axis Y-axis Center point (I, J) Center point (I, J) Center point Center point (I, J) (I, J) X-axis Start point Start point X-axis Start point Start point Z=0 Z=0 Z=0 Z=0 G03 (Counterclockwise interpolation) G02 (Clockwise interpolation)  If G18 is used, and the postion of a y-axis does not change, helical interpolation will be equivalent to circular interpolation.

Z-axis Z-axis End point (x, y, z) Start point Center point End point (x, y, z) (I, K) Start point Center point Center point End point (I,K) ( x, z) Y=0 End point Y-axis (I, K) ( x, z) Y=0 Y-axis (I, K) Center point Start point Start point Y=0 Y=0 X-axis X-axis G03 (Counterclockwise interpolation) G02 (Clockwise interpolation) 9-10