AH500 Motion Control Module Manual Example 2 Absolute coordinates are set. G18 and G02 are used. The arc end point set is (-10, 15, 35) and the arc cent point set is (-10, 0, 5). The output speed set is 2000 Hz. Z-axis End point: (-10, 15, 35) Center point: (-10, 0, 5) Start point: (20, 0, 5) Y-axis X-axis Program: G90; G18; G02 X-10 Y15 Z35 I-30 J0 (omissible) K0 (omissible) F2000; 9-14