Chapter 9 Multiaxial Interpolation 0004 Description: T : Dwell time value If the operand X is used, a second is a unit of measurement for dwell duration. For example, the dwell period set is one second if G4 X1 is used, and the dwell period set is 2.5 seconds if G4 X2.5 is used. If the operand X is used, a millisecond is a unit of measurement for dwell duration. For example, the dwell period set 0.1 seconds if G4 P100 is used, and the dwell priod set is 4.5 seconds if G4 P4500 is used. The dwell period set must be a multiple of 10 millseconds. If the dwell period set is less than 10 milliseconds, the dwell period will become 0 milliseconds.
If the dwell period set is 23 milliseconds, the dwell period will become 20 milliseconds. A dwell period is a time interval between two instructions. Time G4 T 9-19 Instruction code Operand Function G04 X T /P T Dwell Device K 16# F D DD W WW T