Chapter 13 Expansion Storage Device 13.4.1 Backup The operation procedures for device backup are described below, 1. Monitor AH20MC-5A, AH10PM-5A, or AH15PM-5A by PMSoft, and stop the operation under the monitoring. Alternatively, set SM072 to 0 to stop 0100. 2. Set SR214 by a device monitoring table or by external communication. Set bit 12~bit 0 in SR214. The values of bit 12~bit 0 in SR124 represents a backup file name. To backup, set bit 13 in SR214 to 1. To backup devices, set bit 15 in SR214 to 1. For example, if the value in SR214 is A000H, devices will be backed up, the name of the backup file will be 0, and the file 0.csv can be found in \AHMotion\Device\ in a memory card.
The CSV file embodies the data in the devices. As it includes every device, no individual device is to be excluded from being backup. Device parameters can be changed via the CSV file in a general Windows environment. The format of the CSV file is as shown below. The first line indicates the format version of the memory cards for an AH500 series motion control module. PLC Type: The model name of an AH500 series motion control module PLC FWVer: Firmware version of a model 13-5