Chapter 14 DMCNET high occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. If the motor used comes into contact with a limit switch when it returns home, it will stop after an error code is generated. The value in SR1078 (SR1178, SR1278…) is 5 or 6. 1. The value in SR1078 (SR1178, SR1278…) is 5. The motor used rotates clockwise. After a transition in DOG’s signal from low to high occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high occurs. 2. The value in SR1078 (SR1178, SR1278…) is 6. The motor used rotates clockwise.
After a transition in DOG’s signal from low to high occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. If the motor used comes into contact with a limit switch when it returns home, it will stop after an error code is generated. The value in SR1078 (SR1178, SR1278…) is 7, 8, 9, or 10. If the value in SR1078 (SR1178, SR1278…) is 7, 8, 9, or 10, the motor used will rotate counterclockwise, and search for a transition in DOG’s signal. There are three situations. a. The motor used does not find a transition in DOG’s signal or does not come into contact with the positive limit switch specified. Mode 7:
The motor used rotates counterclockwise. After a transition in DOG’s signal from low to high occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high occurs. Mode 8: The motor used rotates counterclockwise. After a transition in DOG’s signal from low to high occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. Mode 9: The motor used rotates counterclockwise. After a transition in DOG’s signal from high to low occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high occurs. Mode 10: The motor used rotates counterclockwise.
After a transition in DOG’s signal from high to low occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. b. The motor used rotates when DOG’s signal is ON. Mode 7: The motor used rotates clockwise. After a transition in DOG’s signal from high to low occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high occurs. Mode 8: The motor used rotates clockwise. After a transition in DOG’s signal from high to low occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. Mode 9: The motor used rotates counterclockwise.
After a transition in DOG’s signal from high to low occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high. Mode 10: The motor used rotates counterclockwise. After a transition in DOG’s signal from high to low occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. c. The motor used comes into contact with the positive limit switch specified. Mode 7: The motor used rotates counterclockwise. After the motor comes into contact with the positive limit switch specified, it will rotate clockwise.
After a transition in DOG’s signal from high to low occurs, the motor will rotate clockwise until a transition in a Z-phase signal from low to high occurs. Mode 8: The motor used rotates counterclockwise. After the motor comes into contact with the positive limit switch specified, it will rotate clockwise. After a transition in DOG’s signal from high to low occurs, the motor will rotate counterclockwise until a transition in a Z-phase signal from low to high occurs. Mode 9: The motor used rotates counterclockwise. After the motor comes into contact with the positive limit switch specified, it will rotate clockwise. After a transition in DOG’s 14-13