AH500 Operation Manual The parameters related to an Ether Link in all the nodes are uploaded. Before the users upload the related parameters, they have to make sure that all the PLCs and all the modules are connected to an Ethernet network, and can connect to NWCONFIG through Ethernet. The connection type that the driver selected in the Driver Name drop-down list box in the Select a Driver window uses must be Ethernet, otherwise the related parameters can not be uploaded. Please refer to section 16.1.3 for more information. Method 1 Click the PLC menu, point to Transfer , and click Upload (Multiple PLCs) . The users can also download the related parameters by clicking on the toolbar.
Method 2 Select All Nodes on the node list, right-click All Nodes , and click Upload (Multiple PLCs) on the context menu. Additional remark After the parameters which include a node not configured in NWCONFIG are uploaded, the node which is not configured in NWCONFIG will be called an asynchronous device, and will be in red. If the setting of an Ether Link includes an asynchronous device, the system does not allow the Ether Link to be monitored, and it does not allow the parameters related to the Ether Link to be downloaded.
11.2.2.8 Deleting Asynchronous Device If the setting of an Ether Link includes asynchronous devices, the system does not allow the Ether Link to be monitored, and it does not allow the parameters related to the Ether Link to be downloaded. Users have to find out the reason for the existence of the asynchronous devices. If the network configuration in NWCONFIG is incorrect, the users have to modify the network configuration, and upload the parameters related to the Ether 11-48