Delta Electronics — 7.2.4 Control Registers

AS Series Module Manual _7 7-8 CR# Name Description Defaults 211 for channel 1 Maximum peak value for channel 1 - 212 The maximum peak value for channel 2 Floating-point format Maximum peak value for channel 2 - 213 - 214 The minimum peak value for channel 1 Floating-point format Minimum peak value for channel 1 - 215 - 216 The minimum peak value for channel 2 Floating-point format Minimum peak value for channel 2 - 217 - 222 The time to record for channel 1 Unit: 1 ms Range: 1–100 (1 ms–1 s) Time to record the digital value for the channels 50 223 The time to record for channel 2 50 240 The number of records for channel 1 Range:

0–500; display the current records - 241 The number of records for channel 2 - 604 Tare measured by channel 1 Display the tare measured by channel 1 - 605 - 606 Tare measured by channel 2 Display the tare measured by channel 2 - 607 - 700– 739 Theoretical calibration for channel 1 Floating-point format Output voltage unit: mV 0 740– 779 Theoretical calibration for channel 2 Floating-point format Output voltage unit: mV 0 4000 –4999 Records for channel 1 Floating-point format 500 records for channel 1 - 5000 –5999 Records for channel 2 Floating-point format 500 records for channel 2 -