Delta Electronics — 8.2.4 Control Registers

AS Series Module Manual _8 8-6 CR# Name Description Att. Default 7 weight measured exceeds the limit, an alarm is triggered. The value should be greater than 1. 8 Filter mode for CH1 0: no filter (default) 1: maximum filter mode 2: average filter mode R/W 0 9 Maximum filter for CH1 Range: 0–8; the bigger the number the stronger the filter R/W 1 10 Average weight measured times for CH1 Range: 1–100 (for FW V1.04: 1–400 is available) R/W 10 11 Upper limit of the zero return for CH1 Floating-point format Determines the current weight as the zero point in the upper/lower range; when the lower range is larger than the upper range, the lower range is read as the upper range and vice versa.

R/W 10 12 13 Lower limit of the zero return for CH1 R/W -10 14 15 Zero point tracking time for CH1 Range: 5–500 Unit: 100 ms R/W 10 16 Zero point tracking range for CH1 Floating-point format Range: 0–10000; 0: disabled R/W 0 17 18 Calibration points for CH1 Range: 2–20 R/W 2 19–58 Calibrated weight for CH1 Floating-point format Calibrated weight of the calibration points 1–20 R/W - 59 Display options for CH2 0: disabled 1: gross weight 2: net weight 3: raw data R/W 1 60 Eigenvalue for CH2 0:1 mV/V 1:2 mV/V 2:4 mV/V R/W 1