Delta Electronics — 8.2.4 Control Registers

Chapter 8 Load Cell Module AS02LC Normal Exchange Area You can view the error code, the channel value, and the state code, as well as the data registers that Explanation correspond to their commands under the Normal Exchange Area tab of the Device Setting dialog box in the HWCONFIG utility in ISPSoft. 8_ 8-9 CR# Name Description Att. Default 241 The number of records for CH2 - 604 Tare weight measured by CH1 Display the tare weight measured by CH1 R/W - 605 - 606 Tare weight measured by CH2 Display the tare weight measured by CH2 R/W - 607 - 700– 739 Theoretical calibration for CH1 Floating-point format Output voltage unit:

mV R/W 0 740– 779 Theoretical calibration for CH2 Floating-point format Output voltage unit: mV R/W 0 4000 –4999 Records for CH1 Floating-point format 500 records for CH1 R - 5000 –5999 Records for CH2 Floating-point format 500 records for CH2 R -