Chapter 8 Load Cell Module AS02LC 8_ 8-11 Input Description Input value Description value 100 Subtract the weight on CH1. Use the subtracted weight as the tare weight and store it in CR604 and CR605 (DWORD). 16#020F Start a new recording for CH1 - CH2. 101 Restore the tare weight stored in CR604 and CR605 to CH1. 16#0211 Stop recording for CH1. 102 Clear the weight measured by CH1 to zero. You might need to execute this command after each power-off. 16#0212 Stop recording for CH2. 103 Subtract the weight on CH2. Use the subtracted weight as the tare weight and store it in CR606 and CR607 (DWORD). 16#021F Stop recording for CH1 - CH2.
104 Restore the tare weight stored in CR606 and CR607 to CH2. 16#0301 Start a theoretical calibration for CH1. 105 Clear the weight measured by CH2 to zero. You might need to execute this command after each power-off. 16#0302 Start a theoretical calibration for CH2. 16#030F Start a theoretical calibration for CH1 - CH2. 16#0501 Restore default settings and clear settings in Flash. 16#0502 Restore default settings and settings in Flash stay intact. 16#6000 Read the current settings from Flash 16#6001 Write the current settings into Flash