Delta Electronics — 4.2.4 Control Registers

Chapter 4 Analog Output Module AS04DA 4_ 4-7 CR# Name Description Atr. Defaults 6 Channel 2 offset 7 Channel 3 offset 8 Channel 4 offset 9 Channel 1 gain Range: -32768 to +32767 R/W 1000 10 Channel 2 gain 11 Channel 3 gain 12 Channel 4 gain 13 Retaining an output sent by channel 1 0: when the PLC stops, the value of the analog output is reset to 0. 1: when the PLC stops, the value of the analog output is retained. R/W 0 14 Retaining an output sent by channel 2 15 Retaining an output sent by channel 3 16 Retaining an output sent by channel 4 17 Refreshing the time for an output sent by channel 1 Range: 10–3200 (100 ms–32000 ms) Unit: 10 ms Any value less than 10 is processed as 0.

Any value larger than 3200 is processed as 3200. Set the value to 0 to disable this function. R/W 0 18 Refreshing the time for an output sent by channel 2 0 19 Refreshing the time for an output sent by channel 3 0 20 Refreshing the time for an output sent by channel 4 0 21 The minimum scale range for channel 1 When the format is set to integer in HWCONFIG, the scale range is invalid. For analog-digital modules, it is much more convenient if the system can convert digital values to floating-point values for earier understanding. Here you can set the minimum and maximum scale ranges of corresponding floating-point values for channels.