ASDA-B3 Wiring 3.5 Wiring for the CN3 communication connector 3.5.1 Wiring for the MODBUS communication connector When the servo drive is connected to the PC via CN3, you can operate the servo drive, PLC, or 3 HMI through MODBUS using the assembly language. The CN3 connector supports the RS-485 communication interface which enables you to connect multiple servo drives simultaneously. Note: B3 -L model: single port (Pin 1 - Pin 8); supports RS-485 only. 8 1 (2) (1) CN3 connector (female); (2) CN3 connector (male) Pin assignment: Note: refer to Chapter 9 for the RS-485 wiring. 3-59 (1) Pin No.
Signal Description 1 - - 2 - - 3, 7 GND ISO _ Signal GND 4 RS-485- The servo drive transmits the data to differential terminal (-). 5 RS-485+ The servo drive transmits the data to differential terminal (+). 6, 8 - -