Delta Electronics — 4.3.5 Monitoring display

Test Operation and Panel Display ASDA-B3 4 4-8 P0.002 Monitoring displayed Description Unit setting value symbol 10 Torque command [Volt] 11 Torque command [%] 12 Average torque [%] 13 Peak torque [%] 14 Main circuit voltage [Volt] 15 Load / motor inertia ratio Note: if it shows 13.0, it means the load inertia ratio is 13. [1 times] 16 IGBT temperature [°C] 17 Resonance frequency (low byte is the first resonance and high byte is the second one) [Hz] 18 0 +5000 0 +5000 0 The absolute pulse number of encoder Z phase equals the homing value, 0. It is +5000 or -4999 pulses when the motor rotates in the positive or negative direction. - Z Z Z 19 Mapping parameter #1:

shows the content of parameter P0.025 (P0.035 specifies the mapping target) - 20 Mapping parameter #2: shows the content of parameter P0.026 (P0.036 specifies the mapping target) - 21 Mapping parameter #3: shows the content of parameter P0.027 (P0.037 specifies the mapping target) - 22 Mapping parameter #4: shows the content of parameter P0.028 (P0.038 specifies the mapping target) - 23 Monitoring variable #1: shows the content of parameter P0.009 (P0.017 specifies the monitoring variable) - 24 Monitoring variable #2: shows the content of parameter P0.010 (P0.018 specifies the monitoring variable) - 25 Monitoring variable #3:

shows the content of parameter P0.011 (P0.019 specifies the monitoring variable) - 26 Monitoring variable #4: shows the content of parameter P0.012 (P0.020 specifies the monitoring variable) -