ASDA-B3 Tuning 5.3 Gain adjustment modes Apart from the auto tuning function described above, there are three other gain adjustment modes you can use to fine tune the system. You can then easily complete tuning by increasing or 5 decreasing the bandwidth response level (P2.031). Follow the tuning procedure in Section 5.1. 5.3.1 Flowchart of Gain adjustment mode Start Adjustment mode 1 P2.032 = 1 Keep estimating the inertia ratio (P1.037) Adjust P2.031 (Bandwidth level) Satisfied with the Yes performance? No Adjustment mode 2 P2.032 = 2 Adjust P2.031 (Bandwidth level) and P1.037 (Inertia ratio) Satisfied with the Yes performance?
No Adjustment mode 3 P2.032 = 3 Adjust P2.031 (Bandwidth level), P1.037 (Inertia ratio), and P2.089 (Command response gain) Satisfied with the Yes performance? No Enter Manual mode P2.032 = 0 You can adjust all parameters in Manual mode Satisfied with the performance? Yes No Complete 5-15