ASDA-B3 Parameters 8.3 Parameter descriptions P0.xxx Monitoring parameters 8 Settings: Displays the firmware version of the servo drive. Settings: For the list of alarms, refer to Section 12.1 Alarm list. S ettings: The parameter setting displayed on the panel. Input the monitoring code to P0.002 to view changes to the variable on the panel. For the list of monitoring variables, refer to Table 8.3 Monitoring variables descriptions. Settings: Y Z U X 8-13 Address: 0000H P0.000★ Firmware version 0001H Default: Factory setting Control mode: All Unit: - Setting range: - Format: DEC Data size: 16-bit Address: 0002H P0.001■ Current drive alarm code (seven-segment display) 0003H Default:
- Control mode: All - 0x0000: alarm clear (same as DI.ARST) 0x0001 - 0xFFFF: displays the alarm code (not writable) Unit: Setting range: Format: HEX Data size: 16-bit Address: 0004H P0.002 Drive status 0005H Default: 1 Control mode: All Unit: - Setting range: -300 to 127 Format: DEC Data size: 16-bit Address: 0006H P0.003 Analog output monitoring 0007H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0077 Format: HEX Data size: 16-bit X MON2 value Z Reserved Y MON1 value U Reserved