Delta Electronics — P0.xxx Monitoring parameters

Parameters ASDA-B3 8 Note: refer to P1.004 and P1.005 for the proportional setting for the analog output voltage. For example: when you set P0.003 to 01 (MON1 is the analog output of motor speed; MON2 is the analog output of motor torque): Motor speed MON1 output voltage = 8 x (Maximum speed x P1.004 100 ) (Unit: volts) MON2 output voltage = 8 x (Maximum torque x P1.005 Motor torque 100 ) (Unit: volts) Settings: Displays the total servo drive operation and Servo On time. The unit is in hours and durations of less than 1 hour are not recorded. The recorded hours are saved when the servo power is off.

8-14 MON1 and MON2 Description MON1 and MON2 value Description value 0 Motor speed (+/- 8 volts / Maximum speed) 4 Torque command (+/- 8 volts / Maximum Torque command) 1 Motor torque (+/- 8 volts / Maximum torque) 5 VBUS voltage (+/- 8 volts / 450V) 2 Pulse command frequency (+8 volts / 4.5 Mpps) 6 Analog output voltage is the set value of P1.101 3 Speed command (+/- 8 volts / Maximum Speed command) 7 Analog output voltage is the set value of P1.102 P 0.004 - Reserved P0.007 Address: 0010H P0.008★ Total servo drive operation time 0011H Default: 0x00000000 Control mode: All Unit: hour Setting range: 0x00000000 - 0xFFFFFFFF Format: HEX Data size:

32-bit High bit Low bit D C B A U Z Y X DCBA Servo On time UZYX Servo power applied time