Parameters ASDA-B3 Settings: Set the value to be monitored in P0.020 through the drive panel or communication. Please refer to 8 P0.002. To get the status, read the communication address through the communication port. Set P0.002 to 26 and the panel displays “VAR-4” and then the value of P0.012. Settings: Set the value to be monitored in P0.021 through the drive panel or communication. Please refer to P0.002. To get the status, read the communication address through the communication port. Settings: Refer to Table 8.3 for the available values. For example, if you set P0.017 to 7, then reading P0.009 displays the motor speed (rpm). Settings: Refer to Table 8.3 for the available values.
Settings: Refer to Table 8.3 for the available values. 8-16 Address: 001AH P0.013★■ Status monitoring register 5 001BH Default: - Control mode: All Unit: - Setting range: - Format: DEC Data size: 32-bit P 0.014 - Reserved P0.016 Address: 0022H P0.017 Select content displayed by status monitoring register 1 0023H Default: 0 Control mode: All Unit: - Setting range: -300 to 127 Format: DEC Data size: 16-bit Address: 0024H P0.018 Select content displayed by status monitoring register 2 0025H Default: 0 Control mode: All Unit: - Setting range: -300 to 127 Format: DEC Data size: 16-bit Address: 0026H P0.019 Select content displayed by status monitoring register 3 0027H Default: 0 Control mode:
All Unit: - Setting range: -300 to 127 Format: DEC Data size: 16-bit