Delta Electronics — P0.xxx Monitoring parameters

ASDA-B3 Parameters 8 Settings: Refer to Table 8.3 for the available values. Settings: Refer to Table 8.3 for the available values. Settings: You can continuously read and write parameters faster if they are not in the same group. Use P0.035 to specify the mapping parameter number through the panel or communication. The value of the parameter that is specified by P0.035 is shown in P0.025. Refer to P0.035 for its settings. Settings: This setting is the same as P0.025, except its mapping target is set in P0.036. 8-17 Address: 0028H P0.020 Select content displayed by status monitoring register 4 0029H Default: 0 Control mode: Unit: - Setting range: Format: DEC Data size: Address:

002AH P0.021 Select content displayed by status monitoring register 5 002BH Default: 0 Control mode: All Unit: - Setting range: -300 to 127 Format: DEC Data size: 16-bit P 0.022 - Reserved P0.024 Address: 0032H P0.025■ Mapping parameter #1 0033H Default: - Control mode: All - Determined by the corresponding parameter P0.035 Unit: Setting range: Format: HEX Data size: 32-bit Address: 0034H P0.026■ Mapping parameter #2 0035H Default: - Control mode: All - Determined by the corresponding parameter P0.036 Unit: Setting range: Format: HEX Data size: 32-bit