Parameters ASDA-B3 8 Settings: This setting is the same as P0.025, except its mapping target is set in P0.037. Settings: This setting is the same as P0.025, except its mapping target is set in P0.038. Settings: This setting is the same as P0.025, except its mapping target is set in P0.039. Settings: This setting is the same as P0.025, except its mapping target is set in P0.040. Settings: This setting is the same as P0.025, except its mapping target is set in P0.041. 8-18 Address: 0036H P0.027■ Mapping parameter #3 0037H Default: - Control mode: All Unit: - Setting range: Determined by the corresponding parameter P0.037 Format: HEX Data size: 32-bit Address:
0038H P0.028■ Mapping parameter #4 0039H Default: - Control mode: All - Determined by the corresponding parameter P0.038 Unit: Setting range: Format: HEX Data size: 32-bit Address: 003AH P0.029■ Mapping parameter #5 003BH Default: - Control mode: All - Determined by the corresponding parameter P0.039 Unit: Setting range: Format: HEX Data size: 32-bit Address: 003CH P0.030■ Mapping parameter #6 003DH Default: - Control mode: All - Determined by the corresponding parameter P0.040 Unit: Setting range: Format: HEX Data size: 32-bit Address: 003EH P0.031■ Mapping parameter #7 003FH Default: - Control mode: All - Determined by the corresponding parameter P0.041 Unit: Setting range: Format:
HEX Data size: 32-bit