Delta Electronics — P1.xxx Basic parameters

ASDA-B3 Parameters Example: When you set U and Y to 1 respectively (and filter width is therefore 0.2 μs), and when the high and low duty width of the command pulse are both larger than 0.8 μs (four times the filter width 0.2 μs), 8 then the pulse command is not filtered out. > 0.8 μs > 0.8 μs When the high or low duty width of the pulse is smaller than the filter width, then it is filtered out. Pulse input Pulse input Filtered signal Filtered signal If the first pulse width is smaller than 0.8 μs, it may be filtered out, and thus two input pulses will be regarded as one pulse. If the pulse width is smaller than 0.2 μs, it will be filtered out.

If the low level pulse width is smaller than 0.8 μs, it may be filtered out, and thus two input pulses will be regarded as one pulse. If this low level pulse width is smaller than 0.2 μs, it will be filtered out. If you use a 125 ns (4 Mpps) input pulse, set the filter value Y to 0 to disable the filter function. Note: when the high-speed pulse specification of the signal is 4 Mpps and the value of the filter is 0, then the pulse is not filtered out. Settings: YX Z U 8-31 0.8 μs Input for control mode and control command Address: 0102H P1.001● 0103H 0x0000 0x000B (B3-F) All Default: Control mode: Unit: - Setting range: 0x0000 - 0x111F Format: HEX Data size:

16-bit YX Control mode setting Z Direction control - - U DIO value control