ASDA-B3 Parameters Z: direction control 8 U: DIO value control (volatile) 0: when you switch the mode, DIO settings (P2.010 - P2.022) remain the same. 1: when you switch the mode, DIO settings (P2.010 - P2.022) are reset to the default corresponding to each mode. Settings: Y Z U X Reserved Reserved X: disable / enable Speed Limit function 0: disable Speed Limit function 1: enable Speed Limit function (only available in T and Tz modes) See the following diagram for Speed Limit setting: Vref (analog command) (0) P1.009 (1) P1.010 (2) Speed Limit command P1.011 (3) Select with DI.SPD0 and DI.SPD1 Y: disable / enable Torque Limit function 0: disable Torque Limit function 1:
enable Torque Limit function 8-33 Z = 0 Z = 1 Positive direction P(CCW) P(CW) Negative direction N(CW) N(CCW) Address: 0104H 0105H P1.002▲ Speed and torque limits Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0011 Format: HEX Data size: 16-bit X Disable / enable Speed Limit function Z Y Disable / enable Torque Limit function U