Parameters ASDA-B3 See the following diagram for Torque Limit setting: Vref (analog command) (0) 8 P1.012 (1) Torque Limit P1.013 (2) command P1.014 (3) Select with DI.TCM0 and DI.TCM1 When using the Torque Limit function, set this parameter to 1 to limit the torque permanently without occupying a DI setting. Alternatively, you can enable or disable the limit function with DI.TRQLM, which is more flexible, but the setting then occupies a DI setting. You can enable the Torque Limit function with either P1.002 or DI. Settings: Y Z U X Reserved Reserved  X: polarity of monitor analog output 0: MON1(+), MON2(+) 1: MON1(+), MON2(-) 2: MON1(-), MON2(+) 3: MON1(-), MON2(-)  Y:

polarity of encoder pulse output 0: pulse output in positive direction 1: pulse output in negative direction Settings: Refer to P0.003 for the analog output setting. 8-34 Address: 0106H P1.003 Encoder pulse output polarity 0107H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0013 Format: HEX Data size: 16-bit X Polarity of monitor analog output Z Y Polarity of encoder pulse output U Address: 0108H P1.004 MON1 analog monitor output proportion 0109H Default: 100 Control mode: All Unit: % (full scale) Setting range: 0 - 100 Format: DEC Data size: 16-bit