Parameters ASDA-B3 8 Settings: Y U X Z Reserved Reverse inhibit YX: acceleration / deceleration time limit (0 - 1270 ms) The setting range is 00 to 7F, with the data format as HEX and unit as 10 ms. If the PR command changes too drastically, it causes mechanical vibration. Set the acceleration / deceleration time limit (the time required for the motor to accelerate from 0 to 3,000 rpm) with this function. If the acceleration / deceleration time of the command is shorter than this limit, the filter takes effect to smooth the acceleration / deceleration which prevents the command from changing too drastically and causing mechanical vibration.
When the filter is functioning, the following error caused by the smooth command is automatically compensated after the command is smoothed, so the final position is not deviated. Example: Set YX to 12, so the acceleration / deceleration time limit is 180 ms. If the acceleration / deceleration time of the PR command is shorter than 180 ms, the filter takes effect. If the acceleration / deceleration time of the PR command is longer than 180 ms, the filter does not take effect. PR speed command (rpm) Original command Filtered command Time (sec) Command slows down and the two commands Command changes drastically so the overlap filter takes effect Note:
if the command does not slow down, the following error of the internal position exceeds the allowable range and then triggers AL404. Z: reserved U: reverse inhibit 0: disable this function. 8-40 Address: 012CH P1.022 PR command special filter 012DH Default: 0x0000 Control mode: PR Unit: - Setting range: 0x0000 - 0x107F Format: HEX Data size: 16-bit YX Acceleration / deceleration time limit (0 - 1270 ms) Z - - U