Delta Electronics — P1.xxx Basic parameters

ASDA-B3 Parameters 1: enable this function. When the value of the current position command is lower than that of the previous position command, the motor does not move. PR position command (PUU) 8 Reverse inhibit function is disabled Time (sec) Reverse inhibit function is enabled Time (sec) Settings: Sets the first low-frequency vibration suppression frequency. When you set P1.026 to 0, the first low-frequency vibration suppression filter is disabled. Settings: Sets the gain of the first low-frequency vibration suppression. The higher the value, the better the position response. If you set the value too high, the motor may not operate smoothly. The suggested value is 1.

Set P1.026 to 0 to disable the first low-frequency vibration suppression filter. 8-41 Reverse command command (PUU) Reverse command command (PUU) P 1.023 - Reserved P1.024 Address: 0132H P1.025 Low-frequency vibration suppression frequency (1) 0133H Default: 1000 Control mode: PT / PR Unit: 0.1 Hz Setting range: 10 - 1000 Format: DEC Data size: 16-bit Example: 150 = 15 Hz - - Address: 0134H P1.026 Low-frequency vibration suppression gain (1) 0135H Default: 0 Control mode: PT / PR Unit: - Setting range: 0 - 9 Format: DEC Data size: 16-bit