Delta Electronics — P1.xxx Basic parameters

Parameters ASDA-B3 8 Settings: Sets the second low-frequency vibration suppression frequency. When you set P1.028 to 0, the second low-frequency vibration suppression filter is disabled. Settings: Sets the gain of the second low-frequency vibration suppression. The higher the value, the better the position response. If you set the value too high, the motor may not operate smoothly. The suggested value is 1. Set P1.028 to 0 to disable the second low-frequency vibration suppression filter. Settings: 0: disable the automatic low-frequency vibration detection function. 1: disable the function automatically after vibration suppression. The value resets to 0 automatically.

Auto mode setting description: When the value is 1, vibration suppression is in automatic mode. When the vibration cannot be detected or the vibration frequency is stable, the system automatically resets the parameter to 0 and saves the vibration suppression frequency to P1.025. 8-42 Address: 0136H P1.027 Low-frequency vibration suppression frequency (2) 0137H Default: 1000 Control mode: PT / PR Unit: 0.1 Hz Setting range: 10 - 1000 Format: DEC Data size: 16-bit Example: 150 = 15 Hz - - Address: 0138H P1.028 Low-frequency vibration suppression gain (2) 0139H Default: 0 Control mode: PT / PR Unit: - Setting range: 0 - 9 Format: DEC Data size: 16-bit Address:

013AH P1.029 Auto low-frequency vibration suppression mode 013BH Default: 0 Control mode: PT / PR Unit: - Setting range: 0 - 1 Format: DEC Data size: 16-bit Address: 013CH P1.030 Low-frequency vibration detection 013DH Default: 8000 Control mode: PT / PR Unit: pulse Setting range: 1 - 128000 Format: DEC Data size: 32-bit