ASDA-B3 Parameters Settings: When enabling automatic vibration suppression (P1.029 = 1), the system automatically finds the detection level. The lower the value, the more sensitive the detection, but the system may misjudge 8 noise or treat other low-frequency vibrations as frequencies to be suppressed. If the value is high, the system is less likely to misjudge, but if the mechanical vibration is small, the system may not properly detect low-frequency vibrations. Settings: Y Z U X Y:
options for using the dynamic brake when the servo is in the Servo Off state or an alarm (including EMGS) occurs 7 Bit When the motor reaches PL (CCWL) or NL (CWL), refer to P5.003 for setting the deceleration time. If you set the deceleration time to 1 ms, the motor stops instantly. Note: the function of Bit 6 is only available in PT, PR, S, and Sz modes and is effective only when P1.043 is a negative value. 8-43 P1.031 Reserved Address: 0140H P1.032 Motor stop mode 0141H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0020 Format: HEX Data size:
16-bit X Reserved Z Reserved Y Dynamic brake operation options U Reserved 6 5 4 Bit Function Description Dynamic brake operation options Options for stopping the motor when the servo is in the Servo Off state or an alarm (including EMGS) occurs Bit 5 = 0 and Bit 4 = 0: use dynamic brake Bit 5 = 0 and Bit 4 = 1: motor runs freely Bit 5 = 1 and Bit 4 = 0: use dynamic brake first, then let the motor run freely once the speed is slower than the value of P1.038 Trigger stop command when AL022 occurs 0: disable this function 1: when P1.043 is a negative value and AL022 occurs, the servo drive commands the motor to decelerate to 0 in the Servo On state Reserved - P1.033 Reserved