Delta Electronics — P1.xxx Basic parameters

Parameters ASDA-B3 8 Settings: P1.034, P1.035, and P1.036 represent the acceleration time for the Speed command from zero to the rated speed. You can set each parameter individually. When using an internal command, if you set P1.036 to 0, the acceleration and deceleration follow a trapezoid-curve; when using an analog command, you must set P1.036 larger than 0 so that the acceleration and deceleration follow a trapezoid-curve. Settings: P1.034, P1.035, and P1.036 represent the deceleration time for the Speed command from the rated speed to zero. You can set each parameter individually.

When using an internal command, if you set P1.036 to 0, the acceleration and deceleration follow a trapezoid-curve; when using an analog command, you must set P1.036 larger than 0 so that the acceleration and deceleration follow a trapezoid-curve. Settings: 0: disable this function. Acceleration / deceleration constant of S-curve: Speed Time P1.036 P1.034 P1.036 P1.036 2 P1.035 P1.036 (ms) 2 2 2 2 2 8-44 Address: 0144H P1.034 S-curve acceleration constant 0145H Default: 200 Control mode: S / Sz Unit: ms Setting range: 1 - 65500 Format: DEC Data size: 16-bit Address: 0146H P1.035 S-curve deceleration constant 0147H Default: 200 Control mode: S / Sz Unit: ms Setting range: 1 - 65500 Format:

DEC Data size: 16-bit Address: 0148H P1.036 S-curve acceleration / deceleration constant 0149H Default: 0 Control mode: PR / S / Sz Unit: ms Setting range: 0 - 65500 Format: DEC Data size: 16-bit