ASDA-B3 Parameters In Speed, PT, and PR modes: Set the torque limit corresponding to 10V (maximum voltage) for the analog torque limit. Torque limit command = Voltage inputЧSetting value 10 (Unit: %) Example: 8 If P1.041 = 10 When the external analog voltage input is 10V, the torque control command = 10VЧ10 10 = 10% When the external analog voltage input is 5V, the torque control command = 5VЧ10 10 = 5% Settings: Sets the delay time from Servo On status to the activation of the magnetic brake signal (DO: 0x08, BRKR). ON SON OFF ON [1*] [ 2* ] BRKR Motor speed (P1.043) (P1.042) [ 2* ] [1*] (P1.038) ZSPD Note: 1.
If the delay time specified in P1.042 has not passed yet and the motor speed is slower than the value of P1.038, the magnetic brake signal (BRKR) is disabled. 2. If the delay time specified in P1.042 has passed and the motor speed is faster than the value of P1.038, the magnetic brake signal (BRKR) is disabled. Settings: Sets the delay time from Servo Off status to the deactivation of the magnetic brake signal (DO: 0x08, BRKR). Refer to P1.042 for the detailed diagram. Note: if P1.043 is a negative value and the servo is off due to an alarm (except for AL022) or emergency stop, this setting does not function. This is equivalent to setting the delay time to 0. 8-47 Address:
0154H P1.042 Enable delay time for magnetic brake 0155H Default: 0 Control mode: All Unit: ms Setting range: 0 - 1000 Format: DEC Data size: 16-bit OFF OFF Address: 0156H P1.043 Disable delay time for magnetic brake 0157H Default: 0 Control mode: All Unit: ms Setting range: -1000 to 1000 Format: DEC Data size: 16-bit