Parameters ASDA-B3 8 Settings: For the E-Gear ratio setting, refer to Section 6.2.5. For multiple E-Gear ratio (numerator) settings, refer to P2.060 - P2.062. Note: do not change the setting in the Servo On state. Settings: If the setting is incorrect, the servo motor is prone to sudden unintended acceleration. Follow these instructions. Setting of pulse input: f2 = f1 x N M Command pulse input range: 1 / 4 < Nx / M < 262144. For the E-Gear ratio setting, refer to Section 6.2.5. Note: do not change the setting in the Servo On state. Settings: The number of single-phase pulse outputs per revolution. The maximum output frequency of the hardware is 19.8 MHz. Note:
In the following circumstances, pulse output of the encoder may exceed the maximum allowable output pulse frequency of the drive, causing AL018: 1. Encoder error 2. The motor speed is faster than P1.076. 3. If P1.074.Y = 0 and P1.097 = 0, motor speed (rpm)/60 x P1.046 x 4 > 19.8 x 10 6 8-48 Address: 0158H P1.044▲ E-Gear ratio (numerator) (N1) 0159H Default: 16777216 Control mode: PT / PR Unit: pulse Setting range: 1 to (229-1) Format: DEC Data size: 32-bit Address: 015AH P1.045▲ E-Gear ratio (denominator) (M) 015BH Default: 100000 Control mode: PT / PR Unit: pulse Setting range: 1 to (231-1) Format: DEC Data size: 32-bit Command pulse input N Position command f1 M f2 Address:
015CH P1.046▲ Encoder pulse number output 015DH Default: 2500 Control mode: All Unit: pulse Setting range: 1 - 536870912 Format: DEC Data size: 32-bit