ASDA-B3 Parameters 8 Settings: In Speed mode, when the deviation between the Speed command and the motor feedback speed is less than this parameter and the difference reaches the time set in P1.049, the digital output DO.SP_OK (DO code: 0x19) is on. Note: when the deviation between the Speed command and the motor feedback speed exceeds the range set in P1.047, the system recalculates the duration. Diagram: 1. Speed command 2. Feedback speed 3. Obtain absolute value 4. Determine if the absolute value of speed deviation is smaller than P1.047 5. DO.SP_OK is on 6. DO.SP_OK is off 1. Speed command:

the command that you input without acceleration or deceleration, rather than the command from the front end speed circuit. Its source is from the register. 2. Feedback speed: the actual speed of the motor which has been filtered. 3. Obtain the absolute value. 4. Determine whether the absolute value of the speed deviation is smaller than the parameter value. If you set the parameter to 0, DO.SP_OK is always off. If the absolute value is smaller than the parameter, DO.SP_OK is on, otherwise it is off. Control selection of digital output DO.MC_OK (DO code: 0x17). Settings: Y Z U X 8-49 Address: 015EH P1.047 Speed reached (DO.SP OK) range 015FH _ Default: 10 Control mode: S / Sz Unit:

rpm Setting range: 0 - 300 Format: DEC Data size: 16-bit Address: 0160H P1.048 Motion reached (DO.MC OK) operation selection 0161H _ Default: 0x0000 Control mode: PR Unit: - Setting range: 0x0000 - 0x0011 Format: HEX Data size: 16-bit X DO output hold option Z Reserved Y Position deviation alarm (AL380) option U Reserved